Buy ANSI A PERFORMANCE STANDARDS FOR KITCHEN AND VANITY CABINETS from SAI Global. Buy KCMA A Performance And Construction Standard For Kitchen And Vanity Cabinets from SAI Global. Kitchen and vanity cabinets bearing the ANSI/KCMA A certification seal have been extensively tested for their structural integrity, drawer.

Author: Kizragore Faetaur
Country: Belarus
Language: English (Spanish)
Genre: Politics
Published (Last): 20 August 2017
Pages: 307
PDF File Size: 15.80 Mb
ePub File Size: 3.65 Mb
ISBN: 894-1-70319-247-2
Downloads: 40681
Price: Free* [*Free Regsitration Required]
Uploader: Saran

Have something to say? Drawers and drawer mechanisms are tested at 15 pounds per square foot and operated through 25, opening and closing cycles to assure durability.

The strength behind certified cabinetry: ANSI/KCMA A | Woodworking Network

Shelves and bottoms are loaded at 15 pounds per square foot to ensure no excessive deflection or joint failure on the cabinet or mounting system.

To test the ability of the drawer-front assembly to withstand the impact of closing the drawer under normal use, a 3-pound weight is dropped 8 inches against the drawer assembly. This ensures the cabinets will live up to your expectations. To test the strength of base-front joints, a load of pounds is applied against the inside of cabinet-front stiles for cabinets with a drawer rail, or pounds for cabinets without a drawer rail, to ensure aansi front joints amsi will not open during stress in service or during installation.

For more information on the certification process, or to find manufacturers of certified cabinetry, visit KCMA. To test the ability of cabinet doors and connections to withstand impacts such as children may cause in falling against a cabinet, or running into it with a tricycle, a pound sandbag is used to strike the center of a closed cabinet door and repeated with the door opened to a degree angle.

The cycle is repeated five times. Your Email has been successfully sent! A 3 pound steel ball is “drop tested” against shelves, cabinet bottoms and drawer bodies to ensure cabinets will withstand dropping of aansi and other items. View the discussion thread. To be certified, cabinetry must first meet the following 14 construction requirements: To test the ability of doors, door-holding devices, hinges and attachment devices to operate under the stress of normal use, doors are opened and closed through a full degree swing for 25, cycles.

The maximum number of products that can be compared is 4. Cabinet finishes are inspected to ensure that stringent standards of appearance are also met. The door must remain weighted ahsi 10 minutes, after which the door and hinges must show no visible signs of damage, and connections between cabinet-and-hinge and door-and-hinge must show no sign of looseness.

TOP Related Articles  ACV HEMORRAGICO TRATAMIENTO EBOOK

To test the a116.1 of drawers and drawer mechanisms to operate with loading during normal use, z161.1 are loaded at 15 pounds per square foot and operated through 25, cycles. These tests create, in accelerated form, the cumulative effects of years of normal kitchen conditions of pre-finished cabinets.

Please refine your selection. The weighted door is slowly operated for 10 cycles from 90 degrees open to 20 degrees open, and returned to the degree position. The drawers must then remain operable with no failure in any part of the drawer assembly or operating system, and drawer bottoms must not be deflected to interfere with drawer operation. On all cabinets, the shelves and bottoms are loaded at 15 pounds per square foot, with the weight maintained for seven days to ensure that there is no excessive deflection and no visible sign of joint separation or failure of any part of the cabinets or the mounting system.

Welcome to our redesigned homepage! Share your thoughts with us in the comments below. Cabinets are impact tested by striking the center of a closed and open door with a 10 pound sand bag.

A 3 pound weight is dropped 10 times against the drawer assembly to ensure that the drawer front assembly will withstand the impact of closing. After ani drops, there must be no evidence of looseness or structural damage to the drawer-front assembly that impairs its operation.

The strength behind certified cabinetry: ANSI/KCMA A161.1

After the test the drawer must not be damaged and must operate as before the test, with no visible sign of joint separation or failure of any part of the cabinet or mounting system. Doors are opened and closed for 25, cycles to ensure durability under the stress of normal usage. To test the ability of the finish to w ithstand hot and cold cycles for prolonged periods, a cabinet door is placed in a hotbox at F and 70 percent relative humidity for one hour, removed and allowed to return to room temperature and humidity conditions, and then placed in a coldbox for one hour at -5F.

These include participation and review by consumer and supplier organizations, builders, remodelers, the U. In order to be certified, cabinets must also undergo eight categories of testing, covering structural integrity, drawer and door operation and finish quality see sidebar below.

A hour soap and water solution test checks the finish’s ability to withstand exposure to detergents and moisture. For information on the certification or to locate a certified cabinet manufacturer, visit the Certifications portal at A16.1.

TOP Related Articles  GLOSARIO TEOSOFICO BLAVATSKY PDF

Finish is exposed to vinegar, grape juice, olive oil, lemon juice, proof alcohol and more to ensure no appreciable discoloration, stain or whitening of the finish occurs. To test the wnsi of doors, hinges, and means of attachment to withstand loading, 65 pounds of weight is applied on the door.

In addition, mounted wall cabinets are gradually loaded to pounds to ensure no visible sign of failure in the cabinet or the mounting system. To test the ability of the finish to withstand substances typically found in the kitchen and bath, exterior exposed surfaces of doors, front frames, drawer fronts and end panels are subjected to vinegar, lemon, orange and grape juices, tomato catsup, coffee, olive oil, and proof alcohol for 24 hours and to mustard for one hour.

Mastercraft Cabinets | KCMA Certification Program, ANSI Standards

These verify the structural integrity and strength of the cabinets. Scroll Down for more stories.

The cabinet door must operate as ansk the test and show no damage or sign of separation or failure in the system. A load of up to pounds is applied against the inside of cabinet fronts to ensure reliable front joints. To test the ability of the finish to withstand high heata cabinet door is placed in a hotbox at F and 70 percent relative humidity for 24 hours.

KCMA Certified

Snsi has sponsored the nationally recognized cabinet testing and certification program for more than 45 years. The finish must then show no appreciable discoloration and no evidence of blistering, cold checking, or other film failure.

To test the ability of the finish to withstand long periods of exposure to a detergent and water solution, a cabinet door edge is subjected to exposure to a standardized detergent formula for 24 hours. Skip to main content. They should also be filled and sanded, edgebanded, or otherwise finished to ensure compliance with the performance standards. Installed wall cabinets are loaded with pounds to ensure that the cabinet will accept net loading in compliance 1a61.1 ANSI A The door edge must then anei no delamination or swelling and no appreciable discoloration or evidence of blistering, checking, whitening, or other film failure.

Cabinet doors are weighted with 65 pounds and operated 10 times to test the ability of door and hinges to withstand loading. Your recommendation is being sent!